Type: Engine, Type number: KTTA50-G GENERATOR 1500KVA ...
Type: Engine, Type number: KTTA50-G GENERATOR 1500KVA ...
Genset Model C22 D5, 22kVA Standby, 20kVA Prime, X2.5G2, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine X2.5G2 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Oil Heater : None Supplied Engine Speed Governing : Mechanical Droop Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator PI144D, 12 Leads, 50 Hertz (Hz), 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Gen ...
C28 D5 Enclosed A044B088 Genset Model C28 D5, 27.5kVA Standby, 25kVA Prime, X2.5G2, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine X2.5G2 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Oil Heater : None Supplied Engine Speed Governing : Mechanical Droop Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator PI144F, 12 Leads, 50 Hertz (Hz), 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator ...
C33 D5 Enclosed A044B089 Genset Model C33 D5, 33kVA Standby, 30kVA Prime, X3.3G1, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine X3.3G1 Engine Air Cleaner - Duty Rating : Normal Duty Engine Oil Heater : None Supplied Engine Speed Governing : Mechanical Droop Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator PI144G, 12 Leads, 50 Hertz (Hz), 380 - 416V, 163C, Emergency Standby Power (ESP) Main Generator Heater : None Supplied Genset Housing Sound Attenuated, S ...
C38 D5 Enclosed A044B090 Genset Model C38 D5, 38kVA Standby, 35kVA Prime, X3.3G1, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine X3.3G1 Engine Air Cleaner - Duty Rating : Normal Duty Engine Oil Heater : None Supplied Engine Speed Governing : Mechanical Droop Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator PI144H, 12 Leads, 50 Hertz (Hz), 380 - 416V, 163C, Emergency Standby Power (ESP) Main Generator Heater : None Supplied Genset Housing Sound Attenuated, S ...
C44 D5 Enclosed A041C003 Genset Model C44 D5, 44kVA Standby, 40kVA Prime, S3.8G4, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire ENGINE S3.8G4 Engine Air Cleaner - Duty Rating : Normal Duty Engine Oil Heater : None Supplied Engine Speed Governing : Mechanical Droop Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC224C, 12 Leads, 50 Hertz (Hz), 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match ...
C66 D5 Enclosed A041C011 Genset Model C66 D5, 66kVA Standby, 60kVA Prime, S3.8G7, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire ENGINE S3.8G7 Engine Air Cleaner - Duty Rating : Normal Duty Engine Oil Heater : None Supplied Engine Speed Governing : Mechanical Droop Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC224F, 12 Leads, 50 Hertz (Hz), 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match ...
C110 D5 Enclosed A040P845 Genset Model C110 D5, 110kVA Standby, 100kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTA5.9G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274C, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : N ...
C150 D5 Enclosed A047W023 Genset Model C150 D5, 150kVA Standby, 136kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTAA5.9G6 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274E, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Ge ...