Effluent plant for waste water treatment. Includes: - Mixing and
equalisation tanks 1, 140 m³ - Mixing and equalisation tanks 2, 40
m³ - Mixing and equalisation tanks 3, 80 m³ - Bioreactor 1, 240 m³
- Bioreactor 2, 240 m³ - 2 air compressors for aeration in the
reactors - Secondary sedimentation tank 1, 100 m³ - Secondary
sedimentation tank 2, 100 m³ - Thin sludge tank, 70 m³ - Thick
sludge tank, 90 m³ - Sludge dewatering 1 and 2 - Precipitant tank, 25
m³ - Various process water pumps, Bioreactor capacity 2 x: 240 m³,
Operation / Control: Siemens Simatic S7, Features: Mixing and
equalisation tank 1, 2 & 3; Pumping station 1 - inlet bioreactor;
pumping station 2 - inlet bioreactor; bioreactor 1; bioreactor 2;
pumping station - outlet bioreactors; 2 x air compressor; Precipitant
tank; filling unit; 2 x flocculent mixing station; secondary
sedimentation tank 1 & 2; mixing tank; thin sludge tank; 2 x sludge
dewatering; thick sludge tank